28.5mm to 32mm hose connector

MikeBz

Well-known member
Joined
22 Aug 2005
Messages
1,472
Location
East Anglia
Visit site
I need to join a 28.5mm (or 1+1/8”) ID hose to a 32mm (1+1/4”) ID hose on the raw water intake side of an engine. The only product I can find is this: Stepped Hose Adaptor (13mm to 38mm). I asked ASAP and that was their recommendation, so it ought to be good enough. It just seems a bit hard to spend £20 on a bit of plastic and cut off/discard most of it. Trudesign do a range of unequal connectors but nothing in between 25 and 32mm. With a bit of bronze bar or tube of the right diameter I could get one turned up, but sourcing that in a very small quantity doesn’t look easy. Aluminium would be easy but unanodised I suspect it wouldn’t last long. Any suggestions before I just buy that stepped plastic connector?
 

Alex_Blackwood

Well-known member
Joined
19 May 2003
Messages
1,623
Location
Fareham
Visit site
I need to join a 28.5mm (or 1+1/8”) ID hose to a 32mm (1+1/4”) ID hose on the raw water intake side of an engine. The only product I can find is this: Stepped Hose Adaptor (13mm to 38mm). I asked ASAP and that was their recommendation, so it ought to be good enough. It just seems a bit hard to spend £20 on a bit of plastic and cut off/discard most of it. Trudesign do a range of unequal connectors but nothing in between 25 and 32mm. With a bit of bronze bar or tube of the right diameter I could get one turned up, but sourcing that in a very small quantity doesn’t look easy. Aluminium would be easy but unanodised I suspect it wouldn’t last long. Any suggestions before I just buy that stepped plastic connector?
Have a look here.
35mm > 32mm Silicone Reducer Hose Coupler Intercooler Tube Blue
 

MikeBz

Well-known member
Joined
22 Aug 2005
Messages
1,472
Location
East Anglia
Visit site
Well… I was only thinking of an internal connector, but a silicone reducer would go directly onto the water pump (28.5mm) and I could then use a quality 32mm internal connector (Trudesign) at the other end. The silicone reducers also come in 45 and 90 deg bends, one of which (prob 90deg) would be a neat solution. Thanks all!
 

Daydream believer

Well-known member
Joined
6 Oct 2012
Messages
19,737
Location
Southminster, essex
Visit site
2 short pieces of copper pipe set between a reducer
I do not know what copper life is though.
A plumber will have the copper offcuts & a merchant will have the reducer.
then just solder the 3 bits together. Plumber will do it for you.
Alternatively use Osma plastic pipe & compression fitting between.
 

MikeBz

Well-known member
Joined
22 Aug 2005
Messages
1,472
Location
East Anglia
Visit site
Any reducer will further restrict the flow of water which might be important in relation to the engines cooling.
So I’m decided: 1” BSP skin fitting/ball valve, 32mm hosetail, 32mm inlet & outlet on the strainer, raw water pump has ~28.5mm inlet (which is part of the pump casting and cannot be changed). So with a tapered silicon hose on the pump, 28.5mm at the pump end, 32mm at the other end connected to the pipe from the strainer by a straight connector, the smallest diameter is the inlet to the pump itself. Thanks to @Alex_Blackwood for putting me on that route!
 

Alicatt

Well-known member
Joined
6 Nov 2017
Messages
4,511
Location
Eating in Eksel or Ice Cold in Alex
Visit site
28mm, 32mm, and 2" piping is common in swimming pools and there are plenty of conversion connectors available for them.
I have 28mm Intex valves on the pool but the piping to the solar panels are 32mm and go through a stepped reducer between one and the other.
 

Alex_Blackwood

Well-known member
Joined
19 May 2003
Messages
1,623
Location
Fareham
Visit site
So I’m decided: 1” BSP skin fitting/ball valve, 32mm hosetail, 32mm inlet & outlet on the strainer, raw water pump has ~28.5mm inlet (which is part of the pump casting and cannot be changed). So with a tapered silicon hose on the pump, 28.5mm at the pump end, 32mm at the other end connected to the pipe from the strainer by a straight connector, the smallest diameter is the inlet to the pump itself. Thanks to @Alex_Blackwood for putting me on that route!
Pleased to be of help 🤞it works.
 
Top